STABLO-AP Ar Ionizer - Static Electricity Remover in Argon Gas

STABLO-AP Ar Ionizer - Static Electricity Remover in Argon Gas

Brand: Shimadzu

World’s First Static Charge Removal in Argon Gas Environments

STABLO-AP Ar Ionizer - Static Electricity Remover in Argon Gas – Overview

World’s First Static Charge Removal in Argon Gas Environments

STABLO-AP Ar Ionizer - Static Electricity Remover in Argon Gas – Specs

STABLO-AP Key Specifications

Model Name STABLO-AP STABLO-AP Ar STABLO-AP N₂ STABLO-AP DRY AIR
Operating Environment*1 Typical atmospheric air environment Temp: 0 to 40 °C Humidity: 25 to max. 85 %RH (with no condensation) Argon gas environment*2,*3 Temp: 0 to 40 °C Dew Point: −76 °Cdp (Moisture Concentration 1 ppm) Oxygen Concentration: 1 ppm Nitrogen gas environment*2,*3,*4,*5 Temp: 0 to 40 °C Dew Point: −76 °Cdp (Moisture Concentration 1 ppm) Oxygen Concentration: 1 ppm Dry air environment*2,*3,*4 Temp: 0 to 40 °C Dew Point: −30 °Cdp (Moisture Concentration: 375 ppm)
Static Elimination Method AC corona discharge AC corona discharge AC corona discharge AC corona discharge
Ion Balance*6,*7 ±10 V ±10 V ±10 V ±10 V (Dew Point: −70 °Cdp) ±30 V (Whole operating environment)
Effective Static Removal Range*7 Approx. 300 mm from the outlet Approx. 300 mm from the outlet Approx. 300 mm from the outlet Approx. 300 mm from the outlet
Static Elimination Time*6,*7,*8 Approx. 1 sec. Approx. 2.5 sec. Approx. 5 sec. Approx. 3.5 sec.
Ozone Concentration 0.06 ppm max. (100 mm from discharge port) Not applicable*9 Not applicable*9 0.06 ppm max.*10,*11 (100 mm from discharge port)
Discharge Electrode (Material) Tungsten (durability: 30,000 hours) Tungsten (durability: 30,000 hours) Tungsten (durability: 30,000 hours) Tungsten (durability: 30,000 hours)
Size (unit) Approx. 120 × 87 × 49 mm (Excluding protruding parts) Approx. 120 × 87 × 49 mm (Excluding protruding parts) Approx. 120 × 87 × 49 mm (Excluding protruding parts) Approx. 120 × 87 × 49 mm (Excluding protruding parts)
Weight Approx. 710 g (Main unit: 395 g, Stand: 315 g) Approx. 710 g (Main unit: 395 g, Stand: 315 g) Approx. 710 g (Main unit: 395 g, Stand: 315 g) Approx. 710 g (Main unit: 395 g, Stand: 315 g)
Rated Electric Power Supply DC 24 V, 0.1 A DC 24 V, 0.1 A DC 24 V, 0.1 A DC 24 V, 0.1 A
Input Power Supply AC 100 V–240 V, 0.58 A, 50/60 Hz*12 AC 100 V–240 V, 0.58 A, 50/60 Hz*12 AC 100 V–240 V, 0.58 A, 50/60 Hz*12 AC 100 V–240 V, 0.58 A, 50/60 Hz*12
*1 It features an auto-off function to reduce wear on the discharge needle (automatically stops 15 minutes after ion irradiation).
*2 To achieve the specified performance, allow the ionizer to acclimate in the operating environment for at least 24 hours to ensure moisture dissipates from the ionizer body.
*3 Pressure reduction in the glove box pass box is permissible down to −0.1 MPa.
*4 Do not place any conductive materials around the ionizer or in the space between the ionizer and the object for static elimination. The ions may be attracted, causing a deterioration in static elimination performance.
*5 When installing a nitrogen gas environment model in an AP-AD/AP series balance, we recommend extending the ion irradiation time setting from 10 seconds to 30 seconds.
*6 This shipping inspection criterion is measured with a 20 pF 150 × 150 mm CPM (charged plate monitor) plate placed at a 100 mm distance from the center of the outlet.
*7 When using the ionizer in an environment with airflow, such as a purge-type glove box, make sure to direct the ionizer outlet along the direction of the airflow.
*8 Time for 1 kV of static charge to decrease to 100 V or less (at 100 mm distance).
*9 STABLO-AP Ar and N₂ do not generate ozone, because oxygen does not exist in an Argon gas and Nitrogen gas environment.
*10 Please ensure adequate ventilation, as ozone concentrations may increase near the irradiation port (within 50 mm) and in enclosed spaces, which may cause irritation to the nose and throat.
*11 When using it installed on an AP-AD/AP series balance, the ozone concentration will be higher inside the draft shield due to the enclosed space. Please leave the ion irradiation time at the default setting of 10 seconds, and do not perform continuous ion irradiation for more than 10 seconds.
*12 The input power supply may change without notice.

STABLO-AP Ar Ionizer - Static Electricity Remover in Argon Gas – Downloads

Download the latest brochure.

  • PDF

    Shimadzu Analytical and Measuring Instruments

    103 KB

    Download
  • PDF

    STABLO AP Ar Brochure

    478 KB

    Download